Most lockout tagout training programs can show a sign-in sheet. Fewer can show that the mechanic called in at 2 a.m. remembers every energy source on the machine. OSHA's standard asks for more than the sheet: employees must acquire the knowledge and skills to apply, use and remove energy controls, and the training must be kept up to date.
As of October 2026, OSHA's posted preliminary list of the most frequently cited standards (fiscal year 2026) ranks Control of Hazardous Energy (lockout/tagout) third. A review of OSHA investigation summaries of lockout/tagout-related deaths in US manufacturing found that "Lockout procedures were not even attempted in the majority (at least 58.8%) of fatal incidents reviewed" (Bulzacchelli et al., 2008).
Table of Contents
The rule is 29 CFR 1910.147, The control of hazardous energy (lockout/tagout). Paragraph (a)(1)(i) applies it to the servicing and maintenance of machines and equipment where unexpected energization, start-up or release of stored energy could injure employees.
The exclusions matter before you build a training plan. Paragraph (a)(1)(ii) leaves out construction and agriculture, maritime work under parts 1915, 1917 and 1918, utility power generation, transmission and distribution installations, electrical hazards covered by subpart S, and oil and gas well drilling and servicing.
Normal production is not covered; servicing or maintenance during it is covered only when an employee must remove or bypass a guard or safety device, or place part of the body in the point of operation or another danger zone during a machine operating cycle (paragraph (a)(2)(ii)). Minor tool changes and adjustments that are routine, repetitive and integral to production are excepted when alternative measures give effective protection. Paragraph (a)(2)(iii) also excludes cord-and-plug equipment that is unplugged with the plug under the worker's exclusive control, and certain hot tap operations.
Paragraph (c)(7)(i) sets the goal for all training: employees must understand "the purpose and function of the energy control program" and gain the knowledge and skills to apply, use and remove energy controls safely. It then sets a different depth of training for three groups.
| Group | Who they are | What training must cover | Paragraph |
|---|---|---|---|
| Authorized employees | People who lock out or tag out machines to service or maintain them | Recognizing hazardous energy sources, the type and magnitude of energy in the workplace, and the methods for isolation and control | (c)(7)(i)(A) |
| Affected employees | People who operate or use the machine being serviced, or work in the area where servicing happens | The purpose and use of the energy control procedure | (c)(7)(i)(B) |
| Other employees | Anyone whose work is or may be in an area where energy control procedures may be used | The procedure, and the prohibition on restarting or reenergizing locked or tagged equipment | (c)(7)(i)(C) |
The roles can change in a single shift. The definition of authorized employee adds that "An affected employee becomes an authorized employee when that employee's duties include performing" servicing or maintenance covered by the standard. A machine operator who clears a jam behind a guard is usually doing covered servicing and needs authorized training, unless the minor servicing exception applies.
Paragraph (c)(7)(i)(A) says "Each authorized employee shall receive training in the recognition of applicable hazardous energy sources," plus "the type and magnitude of the energy available in the workplace," and the methods needed to isolate and control it. In practice, that training follows the six steps the standard lays out in paragraph (d):
Verification is the easiest step to skip under time pressure. Many sites call it the tryout: trying the start controls after isolation to confirm nothing moves. Paragraph (d)(6) requires that before work starts, "the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished." Tryout training belongs in every authorized employee's program.
Tagout adds its own content. When tags are used, paragraph (c)(7)(ii) says employees must also learn the limitations of tags. Among them: "Tags are essentially warning devices affixed to energy isolating devices," they must not be removed without authorization or bypassed, they must be legible and durable, and "Tags may evoke a false sense of security."
Affected employees do not apply locks, but they work next to the equipment. Paragraph (c)(7)(i)(B) reads: "Each affected employee shall be instructed in the purpose and use of the energy control procedure." Under (c)(9), they must also be notified by the employer or authorized employee before controls are applied and after they are removed.
Other employees get the briefest instruction under (c)(7)(i)(C): what the procedure is, and the prohibition on attempts to restart or reenergize locked or tagged equipment. This group can include material handlers and staff from other departments who pass through the area.
The written energy control program itself, including the procedures and the annual periodic inspection under (c)(6), is a separate subject. The inspection ties back to training: for lockout, it includes a review with each authorized employee of their responsibilities under the procedure being inspected (c)(6)(i)(C).
Paragraph (c)(7)(iii) ties retraining to events. Paragraph (c)(7) names no fixed refresher interval.
Retraining is required for all authorized and affected employees when:
Additional retraining is also required whenever a periodic inspection reveals, or the employer has reason to believe, that there are "deviations from or inadequacies in the employee's knowledge or use of the energy control procedures" (c)(7)(iii)(B).
Under (c)(7)(iii)(C), "The retraining shall reestablish employee proficiency" and introduce new or revised control methods and procedures as necessary.
Handing out paper does not meet the requirement. In a 2005 interpretation letter, a requester (name withheld by OSHA) described employees reassigned to new machinery who had never been trained to lock it out, and maintenance staff in a new department who were given copies of the lockout/tagout procedures without any discussion. OSHA answered that these were authorized employees and that "The mere distribution of lockout/tagout procedures will not meet the training requirements" of the standard.
Paragraph (c)(7)(iv) says: "The employer shall certify that employee training has been accomplished and is being kept up to date." It adds: "The certification shall contain each employee's name and dates of training."
"Kept up to date" is the phrase to plan around. A certification shows that training happened on a date, not what an authorized employee recalls about a machine last serviced months ago. Pair the record with a way to check knowledge between events. A training needs assessment is a good place to start mapping which roles need which content.
Lockout knowledge has a timing problem. Some procedures run daily; others cover equipment serviced once a year.
In a study of vineyard workers trained under the EPA Worker Protection Standard, "Training increased the knowledge to 85% on the post-test with the same questions," from a baseline near 75%. Five months later, "Re-test performance (78%) at 5 months revealed a return towards but not back to the pre-test levels" (Anger et al., Journal of Agromedicine, 2009). That study measured pesticide safety knowledge, not lockout, but it shows the kind of slippage (c)(7)(iii)(B) asks employers to catch.
Blank Slate is built for the time between trainings. It is a cognitive-readiness platform built on AI-optimized spaced retrieval. Spaced retrieval combines spaced repetition (reviewing material over time) with retrieval practice (answering from memory instead of rereading).
Blank Slate works on top of the training content your organization already has. Employees answer questions in short sessions (about 60 seconds), 3-4 times a week, adding up to a few minutes a week. True Knowledge Level™, Blank Slate's real-time readiness metric, shows what a person or team knows now. The how it works page shows the setup.
The evidence starts in the classroom. In a randomized trial with university students, Blank Slate's spaced retrieval matched daily review's retention in about one-third of the study time (McHugh et al., 2021). The results carried into demanding field training: US Air Force pararescue trainees rose from 67% to 81% accuracy over 16 weeks while averaging about 100 seconds of use per week (I/ITSEC 2023). On a frontline team, data-center security guards who started below their team's median rose from about 56% to over 90% accuracy in a year-long case study (Smith, MODSIM World 2025), using three short sessions a week, six questions each.
None of these studies measured energy control knowledge. They show knowledge gains, and in the classroom trial matched retention, on very little study time.
Blank Slate does not replace lockout tagout training. It does not deliver authorized employee training, tryout practice on real equipment, retraining after a change, or the certification (c)(7)(iv) requires. It reinforces and measures what employees retain between those events, and it coexists with your LMS, which records completion while Blank Slate shows retention (see the difference).
The standard already gives you the structure: three groups, event-based retraining, and a certification that must stay current. The weak point is the stretch between events, when an authorized employee's knowledge of a rarely serviced machine fades and nothing on paper shows it.
Start with your authorized employees and the equipment they service least often. Check whether they can name each energy source, the isolation method and the verification step without the procedure in hand. The same role-based approach applies to confined space training and HazCom training. See how Blank Slate supports industrial safety teams, or begin by measuring what your crews remember about energy control today.
Authorized employees apply locks or tags to service equipment, so (c)(7)(i)(A) requires training in recognizing hazardous energy sources, the type and magnitude of energy, and isolation methods. Affected employees operate the equipment or work nearby, and (c)(7)(i)(B) requires instruction in the purpose and use of the energy control procedure.
Paragraph 1910.147(c)(7) sets no fixed refresher interval. Authorized and affected employees must be retrained when their job assignments change, when machines, equipment or processes change in a way that presents a new hazard, or when energy control procedures change. Retraining is also required whenever a periodic inspection reveals, or the employer has reason to believe, that there are deviations from or inadequacies in an employee's knowledge or use of the procedures.
Under (c)(7)(iv), the employer must certify that employee training has been accomplished and is being kept up to date. The certification must contain each employee's name and dates of training.
No. OSHA's 2005 interpretation letter says the mere distribution of lockout/tagout procedures will not meet the training requirements for authorized employees. Employees must gain the knowledge and skills to apply, use and remove energy controls. An LMS can record that training happened, and Blank Slate can reinforce and measure what employees retain afterward.
Lockout tagout training is recorded on paper and tested every time someone services a machine. A Knowledge Gap Audit shows what your authorized and affected employees know today and where gaps may exist, before an inspection or an incident finds the gap.